Metallized Polypropylene
(PP)
RFI-Capacitors Class X2
PCM 7.5 mm to 27.5 mm
Special
Features
Reliable
self-healing High degree of interference suppression
due to good attenuation and low ESR According to RoHS 2002/95/EC
Typical
Applications
Class X2
RFI applications to meet EMC regulations Capacitors connected to the mains
between phase and neutral or phase
conductors Installation category II in accordance with
IEC 60664, pulse peak voltage < 2.5 kV
Construction
Dielectric:
Polypropylene (PP) film Capacitor electrodes: Vacuum-deposited Internal construction:
Encapsulation:
Solvent-resistant, flame-retardent plastic case
with epoxy resin seal, UL 94 V-0 Terminations:
Tinned wire Marking:
Colour: Red. Marking: Black
Electrical Data
Capacitance
range: 1000 pF to 2.2 µF
Rated voltage: 275VAC
Continuous DC voltage* (general guide):
< 560V
Capacitance tolerances: ±20%, ±10%
Operating temperature range: -55°C to +105°C Climatic test category: 55/105/56/B in accordance with
IEC
Insulation resistance at +20°C:
C < 0.33 µF: > 15 x
103 M
C > 0.33 µF: > 5000 sec (MxµF)
Measuring voltage: 100V/1 min.
Dissipation factors at +20°C:
tan
Test specifications:
In accordance with DIN EN 60384-14
Maximum pulse rise time:
100 V/µsec for pulses equal to a voltage amplitude with x 275VAC = 390V according to IEC 60384-14 Test voltage: C < 1.0 µF: 2260VDC,
2sec
C > 1.0 µF: 1800VDC, 2sec Reliability: Operational life > 300000
hours
Failure rate < 2 fit (0.5 x Ur and
40°C)
DIN EN 132400
IEC 60384-14/2
UL1414 (250VAC)
C22.2 No.1 (250VAC)
UL 1283 (305VAC)
C22.2 No.8 (305VAC)
40003472
E 134915
E 100438
Mechanical
Tests
Packing
Pull
test on leads: 10 N in direction of leads according to
IEC 60068-2-21 Vibration:
6 hours at 10...2000Hz and 0.75mm displacement
amplitude or 10g in accordance with IEC 60068-2-6 Low air density:
1kPa = 10 mbar in accordance with IEC 60068-2-13 Bump test:
4000 bumps at 390 m/sec2 in accordance
with IEC 60068-2-29
Available
taped and reeled up to and including case size
15x26x31.5 / PCM 27.5mm.
* If safety-approved EMI suppression capacitors are operated with a DC voltage being above the specified AC voltage rating the given approvals are no longer valid (DIN EN 60384-14).
Furthermore the permissible pulse rise time du/dt (Fmax.) will be subject to a reduction according to
Fmax. = Fr x x UAC / UDC
if the DC operating voltage UDC is higher than x UAC