voltage of 2.7VDC Discharge
current up to 2200A Maintenance-free
With cylindrical metal case Series
connection possible According to RoHS 2011/65/EC
Construction
Encapsulation:
Cylindrical aluminium case
Terminations:
Aluminium plates (optional)
Marking: Colour: Black. Marking: Gold
General Data
UR
CN
Dimensions
Part number
Typical applications
D
L
2.7 V
1500F
60
73
SCSCAIC150Z000MV_ _
- Automotive
- Railway technology
- Wind power systems - Uninterruptible power supply (UPS)
- Industry
2000F
60
100
SCSCAIC200Z100MV_ _
3000F
60
136
SCSCAIC300Z200MV_ _
The new SuperCap C60 range offer the possibility of achieving nearly every
capacitance or voltage value by cascading of the cells. The cost-effective manufacturing
of the components in cylindrical cases enables convenient substitution of other brands.
Technical Data
Capacitance:
CN
1500 F
2000 F
3000 F
Capacitance
tolerance:
-
±20%
Rated
voltage:
UR
2.7V
Rated current:
IC
150A
180A
240A
Pulse current:
IP
up to 1200A
up to 1600A
up to 2200A
Internal
resistance:
RDC
0.47m
0.35m
0.29m
Max. stored energy: ±20%
Emax.
5.5kJ
7.5kJ
11kJ
Operating
temperature:
Top
-30°C ... +65°C
Storage temperature:
Tst
-40°C ... +70°C
Weight:
m
275g
355g
500g
Volume:
V
0.21l
0.28l
0.39l
Additional Data
Case:
-
Al99.5
Screw terminations:
-
M8 x 2
.
Comparative Data
Lifetime:
in hours 1):
h
90000
in cycles 2) :
Cycles
500000
Energy
density:
gravimetric:
Ed
5.5Wh/kg
5.7Wh/kg
6.1Wh/kg
volumetric:
Ev
7.3Wh/l
7.4Wh/l
7.8Wh/l
1) Requirements:
lC/CNl < 30%, ESR < 2 times specified limit, Ipeak< 2 times of initial value.
1) Test conditions:
lC/CNl < 30%, ESR < 2 times specified limit, Ipeak< 2 times of initial value
(cycles: charging to UR, 30sec rest, discharging to UR/2, 30sec rest).
Rights reserved to amend design data without
prior notification.
-
Laser welded aluminium plates for series or parallel connection (cascading) of the single cells (optional)
UR
CN
D
L
L1
2.7 V
1500 F
2000 F
3000 F
60
60
60
73
100
136
81
108
144
Part number completion:
Standard:
Aluminium plates:
= 00
= 0L
Dims. in mm.
When connected in series cases should be kept